Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Operation Mechanism, Porcelain Fuse Cutout, Separable Arrester, Shrinkable End Caps, We usually concertrating on acquiring new creative products to fulfill request from our clientele all around the world. Be a part of us and let's make driving safer and funnier jointly! Sticking to the belief of "Creating products of high quality and making friends with people from all over the world", we always put the interest of customers in the first place for Operation Mechanism, Besides strong technical strength, we also introduce advanced equipment for inspection and conduct strict management. All the staff of our company welcome friends both at home and abroad to come for visits and business on the basis of equality and mutual benefit. If you are interested in any of our items, please feel free to contact us for quotation and product details.


  • Incoming operating mechanism for gas insulated switchgear

    Incoming operating mechanism for gas insulated switchgear

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 190-210 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • outgoing mechanism

    outgoing mechanism

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • Hot New Products Operation Mechanism - SF6 Insulated Load Break Switch – Anhuang

    Hot New Products Operation Mechanism - SF6 Insulated Load Break Switch – Anhuang

    Overview The load switch is a kind of switchgear with a simple arc extinguishing device. It uses SF6 gas as the insulation and arc extinguishing medium. It can be used as the closing and breaking load current and overload current. It can also be used as the closing and breaking no-load. Lines, no-load transformers and capacitor banks, etc., all three-position load switches with on, off and grounding functions are simple in structure and affordable. In addition to long life, strong breaking fo...
  • High Quality 33kv Rmu Switchgear - Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch – Anhuang

    High Quality 33kv Rmu Switchgear - Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch – Anhuang

    The use of environmental conditions: 1. Altitude: ≤2000m; Earthquake intensity: not more than eight 2. Air temperature: not higher than +40℃, not less than -30℃. The daily average of relative humidity not more than 90%, monthly average not more than 90%. 3. The installation site with frequent and violent vibration is not suitable for the installation site with water vapor, gas, chemical corrosive deposition, salt spray, dust and dirt, fire and explosion hazards that obviously affect the perfo...
  • 2020 wholesale price Incoming Operating Mechanism - outgoing mechanism – Anhuang

    2020 wholesale price Incoming Operating Mechanism - outgoing mechanism – Anhuang

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • China wholesale High Voltage Switchgear - 12kV 630A loadbreak switch – Anhuang

    China wholesale High Voltage Switchgear - 12kV 630A loadbreak switch – Anhuang

    Technical Parameters 12KV Content Unit Parameter Rated Voltage KV 12 Rated frequency HZ 50 Rated currency A 630 Rated short circuit withstand cu『rent KA 20/25 Rated peak withstand current KA 63 Rated short circuit duration s 2 Rated short circuit cloing current KA 63 Mechnicial life Time 10000 Open triphase dissimilar ms ≤2 Closing triphase dissimilar ms ≤2 Opening average speed mis 3-6 Closing average speed m/s 4-6 Air working step pressure fracture: 22KV -28...
  • High Quality 33kv Rmu Switchgear - outgoing mechanism – Anhuang

    High Quality 33kv Rmu Switchgear - outgoing mechanism – Anhuang

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • Chinese wholesale Modular Mechanism – outgoing mechanism – Anhuang

    Chinese wholesale Modular Mechanism – outgoing mechanism – Anhuang

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • High Quality 33kv Rmu Switchgear - vacuum interrupter – Anhuang

    High Quality 33kv Rmu Switchgear - vacuum interrupter – Anhuang

    The vacuum interrupter uses the wave ceramic as insulating shell, the contact material is CuCr alloy, the longitudinal magnetic field cup structure, with high breaking capacity, high insulation level, strong arc extinguishing ability, long life, small size and easy maintenance, No explosion risk, no pollution, low noise and so on. Main technical parameter Value Rated voltage 12kV Rated current 630A Rated frequency 50Hz Rated short-time power frequency withstand voltage (1 min) 42k...
  • 2020 High quality Operating Mechanism - vacuum interrupter – Anhuang

    2020 High quality Operating Mechanism - vacuum interrupter – Anhuang

    The vacuum interrupter uses the wave ceramic as insulating shell, the contact material is CuCr alloy, the longitudinal magnetic field cup structure, with high breaking capacity, high insulation level, strong arc extinguishing ability, long life, small size and easy maintenance, No explosion risk, no pollution, low noise and so on. Main technical parameter Value Rated voltage 12kV Rated current 630A Rated frequency 50Hz Rated short-time power frequency withstand voltage (1 min) 42k...
  • Hot New Products Operation Mechanism - 12kV 630A loadbreak switch – Anhuang

    Hot New Products Operation Mechanism - 12kV 630A loadbreak switch – Anhuang

    Technical Parameters 12KV Content Unit Parameter Rated Voltage KV 12 Rated frequency HZ 50 Rated currency A 630 Rated short circuit withstand cu『rent KA 20/25 Rated peak withstand current KA 63 Rated short circuit duration s 2 Rated short circuit cloing current KA 63 Mechnicial life Time 10000 Open triphase dissimilar ms ≤2 Closing triphase dissimilar ms ≤2 Opening average speed mis 3-6 Closing average speed m/s 4-6 Air working step pressure fracture: 22KV -28...
  • 2020 High quality Operating Mechanism - outgoing mechanism – Anhuang

    2020 High quality Operating Mechanism - outgoing mechanism – Anhuang

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing: