MV Switchgear Component

  • vacuum interrupter

    vacuum interrupter

    The vacuum interrupter uses the wave ceramic as insulating shell, the contact material is CuCr alloy, the longitudinal magnetic field cup structure, with high breaking capacity, high insulation level, strong arc extinguishing ability, long life, small size and easy maintenance, No explosion risk, no pollution, low noise and so on. Main technical parameter Value Rated voltage 12kV Rated current 630A Rated frequency 50Hz Rated short-time power frequency withstand voltage (1 min) 42k...
  • Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    The use of environmental conditions: 1. Altitude: ≤2000m; Earthquake intensity: not more than eight 2. Air temperature: not higher than +40℃, not less than -30℃. The daily average of relative humidity not more than 90%, monthly average not more than 90%. 3. The installation site with frequent and violent vibration is not suitable for the installation site with water vapor, gas, chemical corrosive deposition, salt spray, dust and dirt, fire and explosion hazards that obviously affect the perfo...
  • Incoming operating mechanism for gas insulated switchgear

    Incoming operating mechanism for gas insulated switchgear

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 190-210 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • outgoing mechanism

    outgoing mechanism

    SF6 Insulated Switchgear Accessories: Manual/Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Switch Contact pressure standard N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average speed m/s 3-6 Closing average speed m/s 4-6 Tri-phase bounce standard m/s ≤2 Three-phase output angle ° 88° Mechanical life Times 10000 Operation strength N ≤110 Drawing:
  • 12kV 630A loadbreak switch

    12kV 630A loadbreak switch

    Technical Parameters 12KV Content Unit Parameter Rated Voltage KV 12 Rated frequency HZ 50 Rated currency A 630 Rated short circuit withstand cu『rent KA 20/25 Rated peak withstand current KA 63 Rated short circuit duration s 2 Rated short circuit cloing current KA 63 Mechnicial life Time 10000 Open triphase dissimilar ms ≤2 Closing triphase dissimilar ms ≤2 Opening average speed mis 3-6 Closing average speed m/s 4-6 Air working step pressure fracture: 22KV -28...
  • SF6 Insulated Load Break Switch

    SF6 Insulated Load Break Switch

    Overview The load switch is a kind of switchgear with a simple arc extinguishing device. It uses SF6 gas as the insulation and arc extinguishing medium. It can be used as the closing and breaking load current and overload current. It can also be used as the closing and breaking no-load. Lines, no-load transformers and capacitor banks, etc., all three-position load switches with on, off and grounding functions are simple in structure and affordable. In addition to long life, strong breaking fo...