We help the world growing since 2004

Loadbreak Switch

  • 38kv 630A Type Four-Position Oil Immersed Loadbreak Switch

    38kv 630A Type Four-Position Oil Immersed Loadbreak Switch

    38kV 630A Type Four-Position Oil Immersed Loadbreak Switch

    With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is "ON", while anticlockwise is "OFF", the rotation angle should be controlled within 90°. In addition, it can be suitable for end power distribution system or ring-network power distribution system if equipped extra configurations.
  • Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)

    Tap Changer Oil Immersed Load Break Switch (WSLII3-125-10)

    Oil Immersed Load Break Switch

    With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is "ON", while anticlockwise is "OFF", the rotation angle should be controlled within 90°. In addition, it can be suitable for end power distribution system or ring-network power distribution system if equipped extra configurations.
  • Tap Changer Oil Immersed Load Break Switch (WSLII3-125-35)

    Tap Changer Oil Immersed Load Break Switch (WSLII3-125-35)

    Oil Immersed Load Break Switch

    With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is "ON", while anticlockwise is "OFF", the rotation angle should be controlled within 90°. In addition, it can be suitable for end power distribution system or ring-network power distribution system if equipped extra configurations.
  • 25kv 630A Two-Position Oil Immersed Loadbreak Switch

    25kv 630A Two-Position Oil Immersed Loadbreak Switch

    25kV 630A Type Two-Position Oil Immersed Load Switch

    With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is "ON", while anticlockwise is "OFF", the rotation angle should be controlled within 90°. In addition, it can be suitable for end power distribution system or ring-network power distribution system if equipped extra configurations.
  • Oil Immersed on Load Rotary Tap Changer Switchgear

    Oil Immersed on Load Rotary Tap Changer Switchgear

    Three Phase 5-Position Oil Immersed Rotary Tap Changer The switch is the tapping regulating and changing equipment of the combined transformer  (power transformer) under the condition of non execitation. It’s applicable to the three phase oil-immersed transformer with the rated voltage 10-35KV, rated current from 63A to 125A. Only under non-excitation condition, can the switch be operates. Switch dimension Mainly paremeter (Note : Use in the insulating strength 35KV transformer) Ins...
  • Medium Voltage Oil Immersed Four-Position 15kV Load Break Switches(LBS)

    Medium Voltage Oil Immersed Four-Position 15kV Load Break Switches(LBS)

    Medium Voltage Oil Immersed Four-Position 15kV Load Break Switches(LBS)   Summarize Four-Position Oil Immersed Load Switch   Anhuang Four-position Oil Immersed Load Switch can apply to the composite transformers with 50Hz AC and rated voltage of 12kV and 35kV. It is a nice and small load switch designed to meet the challenge of continually raising the load capacity of power net while the composite transformers usually have a very limited internal space. It uses the transformer oil a...
  • 25kV 630A Type Two-Position Oil Immersed Load Switch

    25kV 630A Type Two-Position Oil Immersed Load Switch

    Operation-Manual-of-2-position-loadbreak-switch 25kV 630A Type Two-Position Oil Immersed Load Switch   With the transformer oil as insulation and arc extinction medium and energy storing spring operating mechanism, this two-position oil immersed load switch applies to the combined transformer with 50Hz frequency and 25kV rated voltage, it is capable to turn on and off the load current. Equipped with ON and OFF two positions, the clockwise turn is “ON”, while anticlockwise is ...
  • 35kV Oil-immersed two-position loadbreak switch
  • Oil-immersed four-position loadbreak switch

    Oil-immersed four-position loadbreak switch

    12kV 630A Oil-filled four-position load switch is designed for ring-type US-box ring change cabinet designed to meet the IEEE, IEC and GB standards of all requirements. Can be used in grounded or underground systems.  Oil-immersed four-position load switch in the installation, close to the transformer core can minimize the internal connection Cable capacitance, and thus significantly reduce the loop in the ferromagnetic resonance. Both side mounting and top mounting are available For general ...
  • Oil-immersed two-position loadbreak switch

    Oil-immersed two-position loadbreak switch

    Oil-immersed two-position loadbreak switch is mainly used for terminal type American box change, with spring operating mechanism, is a three-phase linkage switch to complete the load breaking and closing operation. By the two two-position load switches can also be composed of ring-type switching system for the ring-type distribution system, two-position switch state: on, off. 10kV rating can be used for wind power projects in the use of transformers. Before use the transformer needs drying. M...